Skip to Content

Drager Pac 8000 | Portable Single Gas Monitor | Multiple Gas Options

(0 review)

With the robust Dräger Pac® 8000, you'll be ready for tough conditions. This nondisposable, personal single-gas detector is a reliable and precise instrument, which detects hazardous concentrations of twenty nine different gases, including special gases like H2, NO2, O3 or COCl2. Measured data can easily be transmitted into the Dräger Gas Detection Connect system via Bluetooth®. 

Sensor Range: 0-20 ppm CL2 Alarms: 0.5/1 ppm CL2

Contact us for a quote today!

0.00 0.00
0.00

  • Sensor Configuration
Terms and Conditions
30-day money-back guarantee
Shipping: 2-3 Business Days

Details


Strong performance for maximum safety

You can count on the Dräger Pac 8000 to give you reliable, precise readings at any time in extreme conditions. Our powerful sensors with a fast T-90 response time ensure quick reactions. In addition to the standard alarms, you can define extra alarm thresholds for TLV®/TWA* and STEL*.

*TLV®/TWA = Threshold Limit Values / Time Weighted Average, STEL = Short Term Exposure Limit

Sensors for special gases

The Pac 8000 can be fitted with sensors for hydrogen (H2), carbon dioxide (CO2), chlorine gas (Cl2), hydrogen cyanide (HCN), ammonia (NH3), nitrogen dioxide (NO2), phosphine (PH3) and organic vapors (OV or OV-A).

The Dräger Pac 8000 performs especially well when detecting different special gases: it can detect ozone (O3) from concentrations as low as 0.02 ppm and phosgene (COCL2) from 0.01 ppm. The Pac 8000 detects nitrogen dioxide (NO2) from concentrations as low as 0.04 ppm.

Robust design – even for the toughest conditions

The Pac 8000 can easily handle extreme conditions. The sensors can tolerate air pressures between 700 and 1,300 mbar and a membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.

Easy handling thanks to clear user guidance

The D-Light indicates whether functionality of the device has been tested and that it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 8000 features clear, clear color coding, this helps minimize the chance of mistakes.

User-friendly display with all important information

The large display is non-verbal and clearly indicates the respective gas concentration. Other important information, such as the unit of concentration and battery capacity, is also displayed. The bright backlighting ensures that all values can be clearly read in low light or dark environments.

360° alarm with various functions

If the Dräger Pac 8000 measures hazardous gas concentrations, it sets off an audible, visual and noticeable vibration alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides and the acoustic signal reaches a volume of 90 dB at 1 ft (30 cm) distance. The display can show the peak concentration measured at any given moment and previous alarms can also be retrieved at a later time even if acknowledged.

Data logger and event logger for analyses and reports

The Pac 8000 records the date and time of concentrations and events. The data can be downloaded to a PC via an interface and processed for future use. The new Gas Detection Connect platform and the integrated X-dock stations allow you to view and download the data from a central cloud-based asset management system. So the data can be available anytime from anywhere.

Bluetooth® communication

With the new Bluetooth® enabled Pac you can wirelessly transmit live measurement values into the Dräger Gas Detection Connect platform. You can easily track the location of the Pac by connecting the device to the Gas Detection Connect gateway app. Dräger Pac devices can also be integrated into third party applications via OpenGATT protocol.

Economical operational costs

All of the versions of the Dräger Pac 8000 are equipped with extremely durable Dräger sensor® XXS and a powerful battery.

The Pac 8000 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes contaminated, you can quickly and easily replace it. The device is then ready to be used with little down time.

Fast function test saves time and money

Function tests and calibrations can be carried out efficiently in the Dräger X‑dock calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to short test duration and the extremely low test gas consumption. The Pac 8000 is simply placed in the bump test station and automatically selects the correct setting.

Technical Data


Key Facts

Application

Technical Data

Features

Approvals

Details


Strong performance for maximum safety

You can count on the Dräger Pac 8500 to give you reliable, precise readings at any time even under extreme conditions. Our powerful sensors with a low t90 response time ensure quick reactions. In addition to the standard alarms, you can define extra alarm thresholds for TLV®* and STEL*.

The Pac 8500 also provides a data and event logger for logging concentrations and events along with the date and time. The data can be loaded on a PC via an interface and processed further there.

* TLV® = Threshold Limit Values, STEL = Short Term Exposure Limit

Two gas detectors in a single-gas format

The Dräger Pac 8500 series offers the following sensor combinations: hydrogen sulfide with carbon monoxide, oxygen with carbon monoxide, or hydrogen sulfide with oxygen. Dual sensors enable detection of even low concentrations – all in one and the same handy device. Measuring two gases at the same time reduces downtime as well. You can take vol.% measurements of oxygen and ppm measurements of carbon monoxide simultaneously using just one gas detector.

Measurement of carbon monoxide with significantly reduced cross sensitivity

In industries where carbon monoxide needs to be measured with hydrogen as a background gas, the measured value for carbon monoxide may be falsified by cross sensitivity. Thanks to the special hydrogen-compensated CO sensor from Dräger, this cross sensitivity to hydrogen is significantly reduced in the display of carbon monoxide. This new feature can eliminate the need to carry two different detectors.

Robust design – even for the toughest conditions

The Pac 8500 is easily handled in even extreme conditions. The sensors can tolerate air pressures between 700 and 1,300 mbar. A membrane filter protects the sensor from foreign matter such as dust and liquids. The shock-proof, chemical-resistant housing meets the requirements specified in the IP68 standard rating.

Easy handling thanks to clear user guidance

The D-Light indicates whether functionality of the device has been tested and if it is ready to use. The housing is also designed with your safety in mind: each sensor variant of the Dräger Pac 8500 features clearly visible color coding, thereby minimizing the chance of mistakes.

User-friendly display with all important information

​The large display is word-free and clearly indicates the respective gas concentration. Other important information, such as the unit of concentration and battery capacity, is also displayed. The bright backlighting ensures that all values are clearly legible in the dark.

360° alarm with various functions

​If the Dräger Pac 8500 measures hazardous gas concentrations, it sets off an audible, visual and perceptible vibrating alarm. Two bright, flashing LEDs on the top and bottom of the device ensure that the alarm is easily visible from all sides. The acoustic signal reaches a volume of 90 dB. The display can show the peak concentration measured at any given moment. Earlier alarms registered can also be retrieved at a later time, even if they have been acknowledged.

The Pac 8500 with oxygen sensor has two additional alarm thresholds in addition to the standard alarm threshold settings. This provides an additional level of safety as a pre-alarm, in addition to the main alarm, can be set for both oxygen enriched and oxygen deficient atmospheres.

Economical operating costs

​All of the versions of the Dräger Pac 8500 are equipped with extremely durable DrägerSensors and a powerful battery.

The Pac 8500 is protected against water, dust and other foreign bodies by a special membrane filter. When the filter becomes heavily soiled in use, you can quickly and easily replace it yourself. The detector is then ready to use again right away. Thanks to the powerful battery, the Pac does not require charging on a daily basis and is easy to handle.

Fast function test saves time and money

​Function tests and calibrations can be carried out especially efficiently in the Dräger X-dock® calibration station. The automatic bump tests in the X-dock are a cost-efficient and convenient solution thanks to the short test duration and the extremely low consumption of test gas. The Pac 8500 is simply placed in the bump test station and automatically selects the correct setting.

Technical Data


Key Facts

Application

Technical Data

Features

Approvals